Powerline 200 AV Adapter with Built-In Outlet

TPL-304E   (Version v1.0R)

  • High speed building-wide networking from any electrical outlet
  • Never lose an electrical outlet with the built in socket
  • Advanced noise filter boosts performance
  • Power Save mode reduces electrical consumption by 70%
  • Use one to transmit and up to 7 TPL-304Es to receive a networked signal

DISCONTINUED PRODUCT

The TPL-304E (Version v1.0R) has been discontinued. It has been replaced by the TPL-423E (Version v1.0R). For a list of discontinued products, click here.

Utility

Release Date: 9/2013
Utility Version: v7.1 Build 0101
WinPcap Version: v4.1.3
OS Compatibility: Windows® 8.1 (32/64-bit), 8 (32/64-bit), Windows 7 (32/64-bit), Vista (32/64-bit), XP (32/64-bit)
Notes:

  1. Added compatibility for Windows® 8/8.1

*Prerequisite: Requires Microsoft® .NET Framework 2.0. Please refer to the Microsoft download center for details on downloading and installing .NET Framework 2.0
***To start the installation, double click the file "Installer_CD.bat***


Filename: Utility_Powerline(v7.1.0101).zip
SHA-1 Checksum: 764C84BB70A7ED416094EBF79A2E91F70CB97023
Date: 7/28/2017
File Size: 6.52 MB

Datasheet

Filename: EN_spec_TPL-304E(V1.0R).pdf
Date: 3/18/2013
File Size: 1.10 MB
Filename: FR_spec_TPL-304E(V1.0R).pdf
Date: 3/18/2013
File Size: 1.11 MB
Filename: GE_spec_TPL-304E(V1.0R).pdf
Date: 3/18/2013
File Size: 1.11 MB
Filename: SP_spec_TPL-304E(V1.0R).pdf
Date: 3/18/2013
File Size: 1.11 MB
Filename: RU_spec_TPL-304E(V1.0R).pdf
Date: 3/18/2013
File Size: 1.89 MB
Filename: IT_spec_TPL-304E(V1.0R).pdf
Date: 3/18/2013
File Size: 1.11 MB

Quick Installation Guide

Filename: EN_Web_TPL-304E_304E2K(1.01).pdf
Date: 3/18/2013
File Size: 1.66 MB
Filename: FR_EN_Web_TPL-304E_304E2K(1.01).pdf
Date: 3/18/2013
File Size: 2.38 MB
Filename: GE_Web_TPL-304E_304E2K(1.01).pdf
Date: 3/18/2013
File Size: 1.22 MB
Filename: PO_Web_TPL-304E_304E2K(1.01)-A.pdf
Date: 3/18/2013
File Size: 1.16 MB
Filename: SP_Web_TPL-304E_304E2K(1.01).pdf
Date: 3/18/2013
File Size: 1.22 MB
Filename: RU_Web_TPL-304E_304E2K(1.01).pdf
Date: 3/18/2013
File Size: 1.93 MB
Filename: EST_Web_TPL-304E_304E2K(1.01).pdf
Date: 3/18/2013
File Size: 968.41 KB
Filename: Dutch_TPL-304E_304E2K(1.01).pdf
Date: 3/18/2013
File Size: 2.90 MB

User's Guide

Filename: UG_TPL-304E_304E2K(1.01).pdf
Date: 3/18/2013
File Size: 910.87 KB

Product Images

JPEG Image
File Size: : 361.73 KB
Date: : 12/14/2010
JPEG Image
File Size: : 348.25 KB
Date: : 2/10/2011
JPEG Image
File Size: : 264.47 KB
Date: : 12/14/2010
JPEG Image
File Size: : 263.65 KB
Date: : 12/14/2010
TIFF Image
File Size: : 3.15 MB
Date: : 12/14/2010
TIFF Image
File Size: : 2.84 MB
Date: : 12/14/2010
TIFF Image
File Size: : 2.54 MB
Date: : 12/14/2010
TIFF Image
File Size: : 2.73 MB
Date: : 12/14/2010
ROHS compliant WEEE crossed-out bin symbol.
Please ensure that the remote PowerLine adapter has an active Ethernet connection to properly synch the units and add the remote unit to the utility. ...
A maximum of 8 TPL-304E adapters can be networked.
Power Off – Power Off Solid Green – Power On Powerline Link/ACT LED Off – No powerline link Solid Green – Successful powerline link Blinking Green – Activity Ethernet Link/ACT LED Off – No Ethernet link Solid Green – Successful Ethernet link Blinking Green – Activity ...
Reset the TPL-304E by pressing and holding in the reset button for approximately 10 seconds. The default network ID is HomePlugAV. You can synchronize the power line devices again by pressing and holding the sync button for 3 seconds on each unit. ...
Ensure you do not have the TPL-304E units connected to surge protectors or to any outlet with appliances. Please also ensure the units are connected to outlets within the same circuit breaker box. Reset the units and ensure they are configured with the same Network ID or use the sync button to conne...
Hardware
StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3x,
HomePlug AV
Interface1 x 10/100Mbps Auto-MDIX RJ-45 Port
1 x electrical power socket with noise filtering (5A max. load)
1 x Sync button
Frequency Band 2 ~ 30 MHz
ModulationOFDM, QAM, QPSK, BPSK, ROBO
Speed
  • Powerline: Up to 200Mbps
  • LAN: 200Mbps with Full Duplex modeM
Utility ComptibilityWindows 7 (32/64-bit), Vista (32/64-bit), XP(32/64-bit)
NodesConnect up to 8 adapters
Encryption128-bit AES
LEDPower, Powerline, Ethernet
Dimension (L x W X H)70 x 143 x 83 mm (2.8 x 5.6 x 3.3 in.)
Weight198 g (7 oz)
Power Source
  • A: 120V (max)
  • EU: 250V (max)
Consumption
  • Active mode: 3.5 Watts (max.)
  • Standby mode: 0.93 Watts (max.)
Temperature
  • Operating: 0° ~ 40° C (32° ~ 104° F)
  • Storage: -10° ~ 55° C (14° ~ 131° F)
HumidityMax. 95% (non-condensing)
CertificationsCE, FCC

PACKAGE CONTENTS

  • TPL-304E
  • Multi-Language Quick Installation Guide
  • CD-ROM (Utility & User's Guide)
  • Cat. 5 Ethernet cable (1.8 m / 6 ft.)