4-Port Kabel/DSL-Firewall-Router mit USB-Druckserver

TW100-BRF114U  

DISCONTINUED PRODUCT

The TW100-BRF114U  has been discontinued. It has been replaced by the TW100-S4W1CA (Version v2.1R). For a list of discontinued products, click here.

Hilfsprogramme

Dateiname: Driver_Utility_TW100BRF114U.zip
Datum: 9/21/2004
Dateigröße: 876.23 KB

Firmware

Description:
Firmware Version: 1.1.1.0
Release Date: 12.2006
Firmware Dateiname: “TW100-BFR114U_FW1110.img”
TW100-BRF114U Cable/DSL 4-Port Firewall Router w/ USB Print Server


Dateiname: Firmware_TW100-BRF114U(1110).zip
SHA-1 Checksum: 2EA27E05725082716281E73660CA80525ED51FF2
Datum: 7/28/2017
Dateigröße: 496.48 KB

Datenblätter

Dateiname: EN_Spec_TW100-BRF114U.pdf
Datum: 7/20/2006
Dateigröße: 293.12 KB
Dateiname: FR_Spec_TW100-BRF114U.pdf
Datum: 7/20/2006
Dateigröße: 298.00 KB
Dateiname: GE_Spec_TW100-BRF114U.pdf
Datum: 7/20/2006
Dateigröße: 298.47 KB
Dateiname: SP_Spec_TW100-BRF114U.pdf
Datum: 7/20/2006
Dateigröße: 295.76 KB
Dateiname: RU_Spec_TW100-BRF114U.pdf
Datum: 7/20/2006
Dateigröße: 1.23 MB

Kurzanleitung zur Installation

Dateiname: QIG_TW100-BRF114U_EN.pdf
Datum: 10/27/2004
Dateigröße: 3.97 MB
Dateiname: QIG_TW100-BRF114U_FR.pdf
Datum: 10/27/2004
Dateigröße: 4.12 MB
German Kurzanleitung zur Installation
Dateiname: QIG_TW100-BRF114U_GE.pdf
Datum: 10/27/2004
Dateigröße: 1.12 MB
Spqnish Kurzanleitung zur Installation
Dateiname: QIG_TW100-BRF114U_SP.pdf
Datum: 10/27/2004
Dateigröße: 4.23 MB
Dateiname: QIG_TW100-BRF114U(estonian).pdf
Datum: 12/2/2005
Dateigröße: 2.24 MB

Bedienungsanleitung

Dateiname: UG_TW100-BRF114U.pdf
Datum: 8/25/2004
Dateigröße: 1.17 MB

Frequently Asked Questions (FAQ)

FAQ
Dateiname: FAQ_TW100-BRF114U.pdf
Datum: 6/30/2006
Dateigröße: 1.28 MB

Produktbild(er)

JPEG Image
Dateigröße: : 344.67 KB
Datum: : 11/10/2006
TIFF Image
Dateigröße: : 3.21 MB
Datum: : 11/10/2006
JPEG Image
Dateigröße: : 420.74 KB
Datum: : 11/10/2006
TIFF Image
Dateigröße: : 0.00 KB
Datum: : 11/10/2006
JPEG Image
Dateigröße: : 384.52 KB
Datum: : 11/10/2006
TIFF Image
Dateigröße: : 3.87 MB
Datum: : 11/10/2006
ROHS compliant WEEE crossed-out bin symbol.
Step 1 Go to Start>Settings>Printers>Add New Printer (WinXP - Start>Printers and Faxes>Add a Printer). Step 2 Select Local Printer. Make sure to uncheck Automatically detect and install my plug and play printer. Click Next. Step 3 Select Create a New Port and select S...
In Windows 98/Me you will need to install the LPR client. For Windows 98/ME you will also need to know the port name that you are printing to (The Port Name is L1. Installing LPR: Step 1 Once the file is downloaded and extracted, Go to Start > Settings > Control Panel > doubl...
The port name is "L1", without the quotes and it is case sensitive.
Open your web browser and type the IP address of the TW100-BRF114U in the address bar. The default IP address is 192.168.0.1. At the login, enter your username (blank) and password (blank). NOTE: If the Setup Wizard starts, click on Cancel. Put a check mark in the Enable box. Rename the serv...
The MAC Address can be found on a label on the bottom of the router. You can alternately find it by doing the following: 1. Open your web browser and type the IP address of the TW100-BRF114U in the address bar. The default IP address is 192.168.0.1. At the login, enter your username (bla...
Click Start then click on the Control Panel. For Windows 2000 click on Start, highlight settings then click on the Control Panel. 1. Double-Click on the Network Connection icon. 2. Right-Click on the Local Area Connection icon then click on Properties. 3. Highlight the Internet P...
1. Open your web browser and type the IP address of the TW100-BRF114U in the address bar. The default IP address is 192.168.0.1. At the login, enter your username (blank) and password (blank). NOTE: If the Setup Wizard starts, click on Cancel. 2. Click on LAN on the left hand side. 3...
The default username & password for the TW100-BRF114U are both (blank). There is no username and password set by default....
The default IP address for the TW100-BRF114U is 192.168.0.1.
1. Locate the reset button on the back of the TW100-BRF114U. 2. Press and hold in the reset button for approximately 15 seconds. This will reset the unit back to its default configuration. ...
A: Open your web browser and type the IP address of the TW100-BRF114U in the address bar. The default IP address is 192.168.0.1. At the login, enter your username (blank) and password (blank). NOTE: If the Setup Wizard starts, click on Cancel. 1. Click on Password on the left hand side. ...
A: Note: The default setting of the router is configured for a Cable connection using a Dynamic IP Address. 1. Open your web browser and type the IP address of the TW100-BRF114U in the address bar. The default IP address is 192.168.0.1. At the login, enter your username (blank) and pass...
Open your web browser and type the IP address of the TW100-BRF114U in the address bar. The default IP address is 192.168.0.1. At the login, enter your username (blank) and password (blank). NOTE: If the Setup Wizard starts, click on Cancel. Click on Advanced then WAN Port on the left hand...
First, verify that the Printer LED on the TW100-BRF114U is lit. If it isn't, ensure that both your printer and the TW100-BRF114U are turned on and that the USB cable is securely connected to the connectors on both devices. Then, try bro...
Option 1: Click the Status button on the TW100-BRF114U's main configuration page. On the Status page, click the Connection Detail button. Click the Release/Renew button to allow the router to refresh the connection to your ISP. Then, try browsing a website such as https://www.TRENDnet.com again with...
You can simply contact your Internet Service Provider's (ISP) Customer Service or Technical Support Department for the correct information. ...
Please verify your hardware and TCP/IP settings again by following the instructions in sections 2-3, and make sure the Power, WAN, and the LAN lights on the AP/Router's front panel are on. Then, try accessing 192.168.0.1 again using your web browser. ...
Hardware
Standards: IEEE 802.3 (10-Base T), 802.3u (100-Base TX)
Protokolle:NAT, PPPoE, HTTP, DHCP, TCP/IP, UDP, PAP, CHAP, RIP1, RIP2, DDNS
WAN:1 x 10/100-MBit/s-Port (Internet)
LAN: 4 x 10/100 MBit/s Auto-MDIX-Ports
Druckeranschluss:1 x USB-1.1-Port
LED-Anzeigen:Gerät: Stromversorgung, Status, WAN
LAN-Ports:Link/Act, 100
Netzteil: 12 V Gleichstrom, 800 mA
Abmessungen (B x T x H):141 x 100 x 27 mm
Gewicht:0,36 kg
Temperatur:
  • Betrieb: 0 °C bis 40 °C
  • Lagerung: -10 °C bis 70 °C
Luftfeuchtigkeit:
  • Betrieb: 0 %- 80 % (nicht kondensierend)
  • Lagerung: 0 %- 95 % (nicht kondensierend)
Zertifizierungen: CE, VCCI
Router
Firewall:NAT-Firewall, SPI-Firewall
Sicherheit:URL-Filter, Zugriffskontrolle, Kennwortschutz, E-Mail-Alarme und -Protokolle
VPN Pass-Through-Abfragen: IPSec, PPTP, L2TP (100 Abfragen)
Druckserver
Protokoll:TCP/IP
Druckverfahren:PTP (Peer-to-Peer) über TCP/IP, LPD

Alle erwähnten Geschwindigkeiten dienen ausschließlich dem Vergleich. Produktspezifikationen, Größe und Form unterliegen unangekündigten Änderungen, und das tatsächliche Aussehen des Produkts kann von dieser Beschreibung abweichen.